9 Program command
-
85
-
9.5.37.
V
Name
Set operating speed
Valid
mode
Direct input/program
V (1 | 2) [, | ] n
Parameter Data
range
Default
(1 | 2)
Axis
1 (operate axis 1), 2 (operate axis 2)
If this parameter is omitted, axis 1 will be
operated.
Syntax
n Operating
speed
10 to 200,000 Hz
10000
Function
Sets the operating speed.
During a continuous operation, setting with a command during an operation becomes
valid immediately, resulting in a multistep speed-change operation.
Request 0>V1
0: V1 = 10000
0>V2
0: V2 = 20000
9.5.38.
VS
Name
Set starting speed
Valid
mode
Direct input/program
V (1 | 2) [, | ] n
Parameter Data
range
Default
(1 | 2)
Axis
1 (operate axis 1), 2 (operate axis 2)
If this parameter is omitted, axis 1 will be
operated.
Syntax
n Starting
speed
10 to 200,000 Hz
1000
Function
Sets the starting speed.
This setting can performed during an operation. However, the command setting will
not be valid until the next operation.
Request 0>VS1
0: VS1 = 1000
0>VS2
0: VS2 = 2000