6 Connection
-
19
-
6.4 Connecting the driver (CN3 · CN4
∗
EMP402
only
)
6.4.1.
Connection method
Use the AXIS connector (26 pins) for connection with the driver.
Plug the AXIS connectors for the first- and second-axis drivers into
CN3 and CN4, respectively, and tighten them with screws.
Screws
CN3
CN4
CN3·CN4 signal table
Pin No.
Signal
Description
Pin No.
Signal
Description
1
+CW-P output
(+PULSE output)
CW pulse (pulse)
14
- No
connection
2
-CW-P output
(-PULSE output)
CW pulse (pulse)
15
- No
connection
3
+CCW-P output
(+DIR. output)
CCW pulse
(
Direction of rotation
)
16 +CCR
output
Counter-clear
4
-CCW-P output
(-DIR. output)
CCW pulse
(
Direction of rotation
)
17
-CCR output
Counter-clear
5
END input
END signal from driver
18
GND
GND signal from driver
6
TIM. input
Timing signal from driver
19
- No
connection
7
ALM input
Alarm signal from driver
20
- No
connection
8
+LS input
CW limit sensor
21
- No
connection
9
-LS input
CCW limit sensor
22
- No
connection
10
HOMELS input
Home limit sensor
23
- No
connection
11 SLIT
input
Slit
sensor
24 - No
connection
12
+12 V output
Power supply terminal
for sensor
(140 mA max.)
25
+5 V output
Power supply terminal
for timing signal
(20 mA max.)
13
GND
GND for sensor
26
GND
GND for timing signal
•
Outputs to driver (1 to 4 and 16, 17 pins)
Inputs from driver (5 to 7 and 18 pins)
Sensor (8 to 13 pins)
For timing signals (25 and 26 pins)
•
Shown in parentheses is the information for 1-pulse output mode.
Pins 25 and 50 of CN1 and pins 13, 18 and 26 of CN3/CN4 are connected internally.
Содержание EMP400 Series