9 Program command
-
67
-
9.5.9.
EDIT
Name
Edit sequence program
Valid
mode
Direct input
EDIT [, | ] n
Parameter Data
range
Default
Syntax
n Sequence
program
number
0 to 31, 99
Function
A sequence program can be edited from the line editor.
If the sequence program number is not entered, a list of sequence program numbers
and the line numbers will be displayed. The number of remaining lines will be
displayed in a message.
Request 0>EDIT
SEQUENCE DIRECTORY:
Seq.0 0Steps. Seq.1 0Steps. Seq.2 0Steps.
Seq.3 0Steps. Seq.4 0Steps. Seq.5 0Steps.
Seq.6 0Steps. Seq.7 0Steps. Seq.8 0Steps.
Seq.9 0Steps. Seq.10 0Steps. Seq.11 0Steps.
Seq.12 0Steps. Seq.13 0Steps. Seq.14 0Steps.
Seq.15 0Steps. Seq.16 0Steps. Seq.17 0Steps.
Seq.18 0Steps. Seq.19 0Steps. Seq.20 0Steps.
Seq.21 0Steps. Seq.22 0Steps. Seq.23 0Steps.
Seq.24 0Steps. Seq.25 0Steps. Seq.26 0Steps.
Seq.27 0Steps. Seq.28 0Steps. Seq.29 0Steps.
Seq.30 0Steps. Seq.31 0Steps. Config
∗
0Steps.
∗
1000Steps free.
∗
Config refers to sequence program 99.
9.5.10.
EEN
Name
Set END input
Valid
mode
Direct input/program
EEN (1 | 2) [, | ] n
Parameter Data
range
Default
(1 | 2)
Axis
1 (select axis 1), 2 (select axis 2)
If this parameter is omitted, axis 1 will be
selected.
Syntax
n Validity
of
END input
0 (invalid), 1 (valid)
0
Function
After the motor operation ends, validates or invalidates the END input from a servo
motor or the
driver. Always set this to “valid” when using a servo motor or
. When this is set to “valid,” if END input does not turn on within one second
after the end of pulse output from the controller, ALM output will turn on and the
sequence program will end.
Request 0>EEN1
0: EEN = 1
0>EEN2
0: EEN2 = 1