9 Program command
-
81
-
9.5.32.
SEN
Name
Set the home-position detection mode
Valid
mode
Direct input/program
SEN (1 | 2) [, | ] n
Parameter Data
range
Default
(1 | 2)
Axis
1 (select axis 1), 2 (select axis 2)
If this parameter is omitted, axis 1 will be
selected.
Syntax
n
Sensor mode 2 (2-sensor mode), 3 (3-sensor mode)
3
Function
Specifies the number of sensors installed in the system.
Configure the setting to 2-sensor mode if ±LS only, and to 3-sensor mode if
HOMELS is present.
Request 0>SEN1
0: SEN1 = 2
0>SEN2
0: SEN2 = 2
About the home-position detection modes
There are two operation modes for mechanical home seeking: the 2-sensor mode (constant-speed
operation) and the 3-sensor mode (high-speed operation).
Choose the mode according to the number of sensors installed in the system.
•
2-sensor mode
Uses two sensors, +LS and -LS, and returns to the
mechanical home at the starting speed (VS).
Mechanical home will be LS or -LS.
VS
VS
2-sensor mode
CW
CCW
-LS
+LS
•
3-sensor mode
Uses three sensors: +LS, -LS and HOMELS. Since there
are three sensors checking the location of the motor,
high-speed return to the mechanical home position is
possible regardless of the motor’s position.
Under the three-sensor mode, HOMELS is the mechanical
home position
3-sensor mode
CW
CCW
-LS
+LS
HOMELS
VS
V
VS