20
SECTION 1
Compon
ent
Na
me
s and
F
unct
ions
CIDRW System
User’s Manual
SECTION 1
Product Outline
No.
Name
Function
1
POWER indicator (green)
An indicator that indicates whether the power is ON or OFF. Lit while the power is ON.
2
OPERATING indicator (green) Lit while the CIDRW system status model is operating.
3
ALARMS indicator (green)
Lit when the status in "Alarm Status" of the CIDRW system is Alarm (1).
4
BUSY indicator (green)
Lit when the status in "Operational Status" of the CIDRW system is BUSY.
5
ERROR indicator (red)
When a processing error is detected (when SSACK is other than NO), this indicator is lit
for 50 ms.
6
24 VDC power supply termi-
nals
(with cover)
Connect to the 24 VDC power supply.
7
Frame ground terminal
(with cover)
The grounding wire is connected here. (Ground to 100
Ω
or less)
8
MODE switch
Used to select the mode of operation.
Refer to page 52.
0: Normal Operation mode. When mounting the Controller, set the switch to this posi-
tion.
3: Setting mode, selected to set information such as the communications conditions.
When the switch on the bottom face of the Controller cannot be accessed, the opera-
tion mode can be changed from the host device while the switch is left at the 0 set-
ting.
1 to 2, 4 to 7:
Setting prohibited
9
RESET switch
Restarts the CIDRW Controller.
10 SECS port
Port for connecting the host device. Conforms to SECS I/II.
11 ID port
An Amplifier Unit or Link Unit is connected here.
12 Maintenance port (with cover) Not used. Do not remove the cover.
The V700-L22-V2 does not have a maintenance port.
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......