Product Outline
V640-HAM11-V4 and V640-HAM11-L-V2 Amplifier Units
Functions
• NOISE MEASUREMENT
The levels of noise in the vicinity of the CIDRW Head are measured and the noise level is expressed
numerically in the range "00" to "99.
• Detecting for CIDRW Head status
You can confirm if the CIDRW Head is connected to the Amplifier Unit correctly.
No.
Name
Function
1
Dedicated power supply con-
nector
Connect to the 24 VDC power supply.
2
RS-485 port
When using multiple CIDRW Heads, connect this to the RS-485 port of another Amplifier
Unit or to the multi-connection port of a Link Unit.
3
RS-232C port
Connected to a CIDRW Controller or a host device.
Uses the OMRON proprietary communications protocol.
4
RUN indicator (green)
Turns ON when the Amplifier Unit is in normal operation.
5
COMM indicator (yellow)
Turns ON during communications with the host device or during communications with an
ID Tag.
6
NORM indicator (green)
Turns ON when the communications finish with no error.
7
ERROR indicator (red)
Turns ON when an error occurs during communications with the host device, or during
communications with an ID Tag.
8
CIDRW Head connection port A CIDRW Head is connected here.
9
Setting DIP switches
Used to set the node number, the communications conditions, and the RS-485 terminal
resistance.
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......