42
SE
CTION 2
Con
n
ec
tions
a
nd Wiring
CIDRW System
User’s Manual
SECTION 2
Installation and Connections/Wiring
• Wiring for Connection to a PC/AT Computer (9-pin Connector)
The cable length should be no greater than 15 m.
RS signal control method at the host device
In a 1:N connection, the RS signals generated from the host device by normal control must be input as CS signals. Turn
the RS signals OFF within 15 ms after the completion of data transmission. Correct communications will not be possible
without this control.
Amplifier Unit
V640-HAM11-V4
V640-HAM11-L-V2
D-SUB, 9-pin
Socket type
Metric screw, M2.6
Name
Pin No.
NC
1
RD
2
SD
3
NC
4
SG
5
NC
6
RS
7
CS
8
NC
9
PC/AT Computer
D-SUB, 9-pin
Socket type
#4-40
Pin No.
Name
1
NC
2
RD
3
SD
4
NC
5
SG
6
NC
7
RS
8
CS
9
NC
Ground shielded wires either at the CIDRW Controller side or at the
PC/AT computer side.
SD at host device
RS at host device
ON only during data transmission from the host device
Within 15 ms
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......