37
CIDRW System
User’s Manual
SE
CTION 2
Con
n
ec
tions
a
nd Wiring
SECTION 2
Installation and Connections/Wiring
• Wiring
The cable length should be no greater than 15 m.
CIDRW Controller
V700-L22
D-SUB, 9-pin
Socket type #4-40
Name
Pin No.
NC
1
RD
2
SD
3
NC
4
SG
5
NC
6
RS
7
NC
8
NC
9
PC/AT Computer
D-SUB, 9-pin
Socket type #4-40
Pin No.
Name
1
NC
2
RD
3
SD
4
NC
5
SG
6
NC
7
RS
8
CS
9
NC
Ground shielded wires either at the CIDRW Controller side or at the PC/AT side.