41
CIDRW System
User’s Manual
SE
CTION 2
Con
n
ec
tions
a
nd Wiring
SECTION 2
Installation and Connections/Wiring
• Wiring for Connection to a V700-L22 CIDRW Controller
The cable length should be no greater than 15 m.
Recommended Models
Manufacturer
Model
Cable
Hitachi Cable
CO-MA-VV-SB 5PX28AWG
Connector
Host side
Socket
OMRON
XM2D-0901
Hood
XM2S-0913
Amplifier Unit
side
Socket
XM2D-0901
Hood
XM2S-0911
Amplifier Unit
V640-HAM11-V4
V640-HAM11-L-V2
D-SUB, 9-pin
Socket type
Metric screw, M2.6
Name
Pin No.
NC
1
RD
2
SD
3
NC
4
SG
5
NC
6
RS
7
CS
8
NC
9
CIDRW Controller
V700-L22
D-SUB, 9-pin
Socket type
#4-40
Pin No.
Name
1
NC
2
RD
3
SD
4
NC
5
SG
6
NC
7
RS
8
CS
9
NC
Ground shielded wires either at the Amplifier Unit side or at the CIDRW side.
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......