45
CIDRW System
User’s Manual
SE
CTION 2
Con
n
ec
tions
a
nd Wiring
SECTION 2
Installation and Connections/Wiring
Link Unit
Power Supply
Opening the cover on the top face of the Link Unit exposes the power supply terminals.
• Crimp Terminals
The terminal screws on the terminal block are M3 size. Use appropriate crimp terminals for M3 screws
as shown below.
• Power Supply
Use a power supply that satisfies the following conditions.
Crimp Terminals
Shape
Size
Forked
Round
Condition
Power supply voltage
Output current
Safety standard
24 VDC +10%, -15%
500 mA DC min.
UL Class 2
Recommended Model
Manufacturer
Model
OMRON
S8VS-01524
24 VDC
6 mm max.
6 mm max.
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......