SECTION 6
Appendix
The NVASC attribute can be used only with the V700-L22-V2.
Option
DateInstalled
Date on which the subsys-
tem was installed
RW
N
20 8 bytes
All " " (space) on shipping
DeviceType
CIDR / CIDRW classifica-
tion
RO
N
20 5 bytes
"CIDRW"
HardwareRevisionLevel
Hardware revision number RO
N
20 6 bytes
"VVV.RR"
(VVV = version, RR = revision)
MaintenanceData
Supplier dependent
RW
N
20 80 bytes
V700-L22: The default value is 71
bytes of " " (spaces).
V700-L22-V2: The default value is
80 bytes of " " (spaces).
Manufacturer
Manufacturer's name or ID RO
N
20 17 bytes
"OMRON Corporation"
ModelNumber
Model name according to
the maker
RO
N
20 6 bytes
V700-L22: "L22 ",
V700-L22-V2: "L22V2"
SerialNumber
System serial number
RO
N
20 max. 20 bytes
(Not supported by the CIDRW)
CIDRW Attribute Definitions
Attribute names
Description
Access
Re-
quest
Format and mounting
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......