V700-L22-V2
Item
Specifications
Power supply voltage
24 VDC +10% -15%
Current consumption
150 mA max. (inrush current: approx. 10 A max.)
Ambient temperature
Operating: 0 to +40
°
C
Storage: -15 to +65
°
C (with no icing)
Ambient humidity
Operating: 10% to 85% Storage: 10% to 95% (with no condensation)
Degree of protection
IP20 (IEC60529)
Insulation resistance
50 M
Ω
min. between power supply terminals and the frame ground terminal (500 VDC M)
Dielectric strength
500 VAC (50/60 Hz for 1 minute) applied between both power supply terminals and frame ground
terminal
Vibration resistance
Frequency: 10 to 150 Hz; double amplitude: 0.20 mm; acceleration: 15 m/s
2
for
8 minutes, 10 times each in X, Y, and Z directions
Shock resistance
Shock of 150 m/s
2
in X, Y, and Z directions, 3 times each for 18 repetitions
Ground
Ground to 100
Ω
or less.
Case material
SECC (coating)
Weight
Approx. 560 g
Accessories
Instruction Sheet and resin washers
150
167
28
130
3
151
30
P6X3
130±0.2
151±0.2
4-M4
24
7
(1:2)
4-
φ
4.5
(Unit: mm)
Mounting dimensions
Power indicator
Operation indicators
(mounting holes)
Four, 4.5-dia. holes
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......