SECTION 4
When SECS Is Used
CIDRW System
User’s Manual
SECTION 4
Reading from/Writing to ID Tags
• Read ID
ID Tag Memory Maps
Refer to page 159.
The NVASC attribute can be used only with the V700-L22-V2.
With the V700-L22, if the MID data contains non-visible ASCII characters:
s = 0, MID item length = 0, SSACK = “EE” execution error
• Write ID
ID Tag Memory Maps
Refer to page 159.
S18,F9
Read ID Request
S,H
→
E,reply
1.<TARGETID>
"01"-"31"
S18,F10
Read ID Data
S,H
←
E
L,4
1.<TARGETID>
"01"-"31"
2.<SSACK>
3.<MID>
4.L,s
1.<STATUS1>
⋅
s.<STATUSs>
• NVASC = “NOM”
1) If the MID data contains non-visible ASCII characters:
s = 0, MID item length = 0, SSACK = “EE” execution error
2) If the MID data does not contain non-visible ASCII characters:
Normal response
• NVASC = “ALL”
A normal response is returned even if the MID data contains non-visible ASCII characters.
• NVASC = “STD”
1) If the MID data does not contain visible ASCII characters:
s = 0, MID item length = 0, SSACK = “EE” execution error
2) If the MID data contains non-visible ASCII characters:
The non-visible ASCII characters are deleted and a normal response is returned.
• NVASC = “EXT”
1) If the first data in the CID in the range defined by CIDOF and CIDLN is NULL, an “EE” execution error is returned.
2) If there are no visible ASCII characters between the start of the range defined by CIDOF and CIDLN and NULL, an “EE”
execution error is returned.
3) Any non-visible ASCII characters between the start of the range defined by CIDOF and CIDLN and NULL are deleted
and the MID is returned along with a normal response.
• When the specified target is invalid:
s = 0, MID item length = 0, SSACK = “CE” communications error
• If SSACK is not “NO” (normal), the List of Status will be a list structure of 0 items.
S18,F11
Write ID Request
S,H
→
E,reply
L,2
1.<TARGETID>
"01"-"31"
2.<MID>
• If an MID that is under the length set for the CarrierIDlength attribute is specified, an error occurs and the MID data is not
written.
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......