36
SE
CTION 2
Con
n
ec
tions
a
nd Wiring
CIDRW System
User’s Manual
SECTION 2
Installation and Connections/Wiring
SECS Port
The method for wiring for communications with a host device via the SECS port is explained here.
• Connector
The SECS port on the Controller is a D-SUB 9-pin connector (with #4-40 lock screws). The pin
arrangement is shown below.
Recommended Models
*1: The bending radius of the recommended RS-232C cable is 44 mm.
Pin No.
Signal name
Symbol
Signal direction
Remarks
1
—
NC
—
Not connected
2
Receive data
RD
Input
3
Send data
SD
Output
4
—
—
Output
Always OFF
5
Signal ground
SG
—
6
—
—
Input
Use in the open status.
7
Request send
RS
Output
Always ON during normal operation
8
Clear to send
CS
Input
Operates even if not connected.
9
—
NC
—
Not connected
Manufacturer
Model
Cable*1
Hitachi Cable
CO-MA-VV-SB 5PX28AWG
Connector
Socket
OMRON
XM2D-0901
Hood
XM2S-0913
CIDRW Controller
Host
To the RS-232 port
To the SECS port
The connector rim has electrical continuity with the
GR (frame ground) in the 24 VDC power supply ter-
minals.
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......