Connections and Wiring
CIDRW Controller
Power Supply and Grounding Wires
Connect the wires to the 24 VDC power supply terminals and frame ground terminal.
• Crimp Terminals
The terminal screws on the terminal block are M3 size. Use appropriate crimp terminals for M3 screws
as shown below.
• Power Supply
Use a power supply that satisfies the following conditions.
Be sure to replace the cover after wiring.
Crimp Terminals
Shape
Size
Forked
Round
Condition
Power supply voltage
Output current
Safety standard
24 VDC +10%, -15%
500 mA DC min.
UL Class 2
Recommended model
Manufacturer
Model
OMRON
S8VS-01524
Ground to 100
Ω
or less.
24 VDC
6 mm max.
6 mm max.