68
SE
CTION 3
Set
ting
t
he Communica
tions
Co
nditions
f
or Link
Units
CIDRW System
User’s Manual
SECTION 3
Preparing for Communications
Setting the Communications Conditions for Link Units
Set the communications conditions by setting the DIP switches.
The node numbers for Link Units are fixed. Check that DIP switches 1to 5 are all ON.
Node No. (fixed)
DIP-SW
1
2
3
4
5
ON
ON
ON
ON
ON
Baud Rate
Option
DIP-SW
Description
6
7
38400 bps
ON
ON
Use a consistent baud rate setting within the same system configuration.
19200 bps
OFF
ON
9600 bps (default setting)
OFF
OFF
4800 bps
ON
OFF
RS-485 Terminator
Option
DIP-SW
Description
10
Invalid
OFF
Set ON.
Valid
ON
Node No.
Baud rate
Always OFF
(Not used in this CIDRW system)
RS-485 terminator
Содержание V640-HS61