roller
CIDRW System
User’s Manual
SECTION 3
Preparing for Communications
Reference:
List of Commands
Designation
Command input
Explanation
Parameter designation
(Tag name) = (Set value) <CRLF> Specify the parameter value corresponding to the tag name.
Parameter confirmation ::END
Checks the parameter designations that have been received so
far and, if there is no error, confirms the settings.
Comment
# (Comment) <CRLF> or CRLF
This is ignored as the comment line.
Parameter output
::GET_PARAM
Outputs the set parameters (protocol, SECS, operation).
::GET_SEG
Outputs the set parameters (ID Tag memory map).
::GET_E99SYS
Outputs the set parameters (operations).
::GET_VER
Outputs the set parameters (software revision).
RESET
::EXIT
Restarts the CIDRW Controller.
Tag Name List
Classification
Parameter
Tag name
Setting range
Default setting
Protocol
Baud Rate
S_BAUD
1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200 bps
9600 bps
Device ID
S_DEVID
0 to 32767
0
Time-out between
characters
S_T1
0.1 to 10 s
0.5 s
Protocol time-out
S_T2
0.2 to 25 s
10 s
Response time-out
S_T3
1 to 120 s
45 s
Time-out between
blocks
S_T4
1 to 120 s
45 s
Retry limit
S_RTY
0 to 31
3
Master/slave
S_MS
M: Master
S: Slave
M
SECS
Double block detec-
tion yes/no
S_DB
1: The header of the block currently being received
is compared with the correct block received
immediately before, and double blocks are
detected.
0: Double block detection is not performed.
0
Source ID
S_SRC
0 to 32767
0
Single block No.
S_BNO
0, 1
1
Operation
Baud rate for com-
munications with
Amplifier Unit/Link
Unit
C_BAUD
9600, 19200, 38400 bps
Use a consistent baud rate setting within the same
system configuration.
9600 bps
Number of Heads
count processing
C_HEAD
0 to 31
0:
The number of Heads is automatically
detected at the start. Any increase or
decrease in the number of Heads is auto-
matically detected.
1 to 31: The number of Heads is specified. The
number of Heads detected is compared
with this specified number of Heads. If the
number of Heads changes, for example
because a Head fails, an error (with alarm)
is detected.
If a Head is not connected or an error is
detected with a connected Head, so that
the number of Heads does not match the
specified number, an error (with alarm) is
detected.
0
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......