77
CIDRW System
User’s Manual
SECTION 4
When SECS Is Used
SECTION 4
Reading from/Writing to ID Tags
*1: “PS” is an expansion command for this Unit.
*2: When the TARGET ID is "00" (CIDRW), this is a zero length item.
*3: "EE," "HE," and "TE" are used only with S18F6, S18F8, S18F10, and S18F12.
*4: “CP” and “ST” are expansion commands for this device and can be used only with the V700-L22-V2.
You can set unique state “CP” with the following SECS message.
1) CID Field(CID Max Length): T_CIDLEN
2) Segment name: T_SEGN
3) Segment length: T_SEGL
4) V700-L21 mode or V700-L22-V2 mode: RVER
5) The following timeout times:
RT (response timeout time)
S_T1 (timeout between characters)
S_T2 (protocol timeout)
S_T3 (response timeout)
S_T4 (timeout between characters)
S_RTY (retry limit)
After you set the parameter, send CPVAL = “ST” to confirm the parameter setting. The new value is enabled immediately.
S9F7 Responses
An S9F7 response is given when a message in an illegal format is received from the host device.
"Illegal format" here means that there is a problem with the message composition, such as illegal attributes, or insuffi-
cient or too many items. If other problems relating to the item contents arise, the response is SSACK = "CE" (communi-
cations error).
Communications with the Host Device
Communicate with the host device only after confirming that the CIDRW Controller has started. Also, unstable signals
may occur at the host interface when the CIDRW Controller is started. When initializing operation, clear the reception
buffer at the host device or take other suitable methods to clear unwanted signals.
SSACK
Result status
20
"NO": Normal
"EE": Execution error *3
"CE": Communications error
"HE": Hardware error *3
"TE": Tag error *3
List of STATUS
Status
L,4
1.<PMInformation>
2.<AlarmStatus>
3.<OperationalStatus>
4.<HeadStatus> *2
The STATUS values are included in the PM infor-
mation.
CPVAL
State request
20
V700-L22: "OP", "MT", "PS" *1
V700-L22-V2: “OP”, “MT”, “PS”,*1 “CP”,*4
“ST”*4
TARGETID
Target ID
20
"00"-"31"
"00" indicates the CIDRW Controller itself.
SSCMD
Subsystem com-
mands
20
"ChangeState"
"GetStatus"
"PerformDiagnostics"
"Reset"
Data Item Dictionary
SECS II data items
Name
Format
Value
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......