89
CIDRW System
User’s Manual
SECTION 4
When SECS Is
N
ot U
sed
SECTION 4
Reading from/Writing to ID Tags
Example: Reading the data of pages 1 and 3 of node No.1
If you send a “Read“ command that specified 1 to 2 page to a 1-page only ID Tag, the Amplifier Unit will response 2nd
page data as all zero.
Data Content of the ID Tag
Page 1
12h
34h
56h
78h
90h
12h
34h
56h
Page 2
Page 3
11h
22h
33h
44h
55h
66h
77h
88h
Page 4
SOH Node No.
Response
code
Page 1
Page 3
FCS CR
01h
0
1
0
0
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 0 7 0Dh
Command
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
Binary notation
SOH
Node No.
Command code
Page designation
FCS
CR
01h
0
1
0
1
0
0
0
0
0
0
0
0
1
4
0
5
0Dh
Response
Содержание V640-HS61