CIDRW System
User’s Manual
SECTION 3
Preparing for Communications
Set Parameters for Communications Conditions
Specify the parameters whose settings are to be changed from the terminal software of the host
device. The commands, and the parameters that can be set are indicated below.
The setting mode commands do not conform to SEMI standards.
Use a Hyper Terminal or other terminal software that supports serial communications.
List of Commands
Designation
Command Input
Explanation
Parameter designation
(Tag name) = (Set value) <CRLF> Specify the parameter value corresponding to the tag name.
Parameter confirmation ::END
Checks the parameter designations that have been received so
far and, if there is no error, confirms the settings.
Comment
# (Comment) <CRLF>
or
CRLF
This is ignored as the comment line.
Tag Name List
Classification
Parameter
Tag name
Setting range
Default
setting
Protocol
Baud Rate
S_BAUD
1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200 bps
9600 bps
Device ID
S_DEVID
0 to 32767
0
Time-out between characters
S_T1
0.1 to 10 s
0.5 s
Protocol time-out
S_T2
0.2 to 25 s
10 s
Response time-out
S_T3
1 to 120 s
45 s
Time-out between blocks
S_T4
1 to 120 s
45 s
Retry limit
S_RTY
0 to 31
3
Master/slave
S_MS
M: Master
S: Slave
M
SECS
Double block detection yes/no S_DB
1: The header of the block currently being
received is compared with the correct block
received immediately before, and double
blocks are detected.
0: Double block detection is not performed.
0
Source ID
S_SRC
0 to 32767
0
Single block No.
S_BNO
0, 1
1
Operation
Baud rate for communications
with Amplifier Unit/Link Unit
C_BAUD
9600, 19200, 38400 bps
Use a consistent baud rate setting within the
same system configuration.
9600 bps
Number of Heads count pro-
cessing
C_HEAD
0 to 31
0:
The number of Heads is automatically
detected at the start. Any increase or
decrease in the number of Heads is auto-
matically detected.
1 to 31: The number of Heads is specified. The
number of Heads detected is compared
with this specified number of Heads. If
the number of Heads changes, for exam-
ple because a Head fails, an error (with
alarm) is detected.
If a Head is not connected or an error is
detected with a connected Head, so that
the number of Heads does not match the
specified number, an error (with alarm) is
detected.
0
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......