111
CIDRW System
User’s Manual
SEC
TION 5
When SECS Is Used
SECTION 5
Troubleshooting
• When All the Indicators Are Lit or Flashing
An error has occurred in the CIDRW Controller.
After taking appropriate corrective action, restart the CIDRW Controller and check the indicators.
• When the CIDRW Controller Responds to a Message Transmission
There is a mistake in the CIDRW Controller settings or the sent parameters.
After taking appropriate corrective action, restart the CIDRW Controller and check the indicators.
• When the CIDRW Controller Fails to Respond To Messages Sent to It
There is a mistake in the CIDRW Controller settings or the sent parameters.
After taking appropriate corrective action, restart the CIDRW Controller and check the indicators.
• When an Error Unrelated to Message Transmission and Responses Occurs
There is a mistake in the settings of the CIDRW Controller or Amplifier Unit.
After taking appropriate corrective action, restart the CIDRW Controller and Amplifier Unit and check
the indicators.
POWER
OPERATING
ALARMS
BUSY
ERROR
Main check points
• Supply of 24 VDC power
• The CIDRW Controller may be damaged.
• Mode switch setting (Is the setting 3?)
If the error cannot be resolved after checking,
the CIDRW Controller may be damaged.
• The CIDRW Controller may be damaged.
POWER
OPERATING
ALARMS
BUSY
ERROR
Main check points
• Sent parameters (Are the parameters correct?
Are the settings correct?)
Response
Contents
SETUP_FAILED [
]
The parameters are not updated. The figure in square brackets [ ] indicates the line number
where the error was first detected. If a parity error is detected in the received characters, this
figure is [0].
POWER
OPERATING
ALARMS
BUSY
ERROR
Main check points
• Transmission parameters (Are the parameters
correct?)
• Communications conditions for communica-
tions between the CIDRW Controller and the
host device (baud rate, character composition,
etc.)
• Mode switch setting (Is the setting 3?)
POWER
OPERATING
ALARMS
BUSY
ERROR
Main check points
• Mode switch setting (Is the setting 3?)
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......