87
CIDRW System
User’s Manual
SECTION 4
When SECS Is
N
ot U
sed
SECTION 4
Reading from/Writing to ID Tags
Command
Communications with the Host Device
Communicate with the host device only after confirming that the CIDRW Controller has started. Also, unstable signals
may occur at the host interface when the CIDRW Controller is started. When initializing operation, clear the reception
buffer at the host device or take other suitable methods to clear unwanted signals.
Command Code List
Name
Value
Function
See
READ
0100
When this command is received, the system communicates with the ID Tag, and
reads the specified page(s) of data. Any pages up to a maximum of 16 can be
selected.
WRITE
0200
When this command is received, the system communicates with the ID Tag, and
writes the specified page(s) of data. Any pages up to a maximum of 16 can be
selected.
SAME WRITE
0300
When this command is received, the system communicates with the ID Tag, and
writes the same data in page units to the specified pages. Up to 17 pages, which is
the maximum number of pages for an ID Tag, can be specified.
BYTE WRITE
0400
When this command is received the system communicates with the ID Tag, and
writes data to the area specified by a first address and number of bytes. A maximum
of 128 bytes can be specified.
TEST
10
Sends received data to the host device.
NAK
12
Sends the response made immediately before again.
GET PARAMETER
14
Gets the model number, Firmware version, or another parameter.
GET LAST COM-
MAND
15
Gets the command code of the last command that was executed.
GET COMMUNICA-
TIONS HISTORY
16
Gets the history of communications from when the power was turned ON (total num-
ber of communications, total successful communications, and total number of failed
communications).
CLEAR COMMUNI-
CATIONS HISTORY
17
Clears the communications history.
NOISE MEASURE-
MENT
40
Measures the noise in the vicinity of the CIDRW Head.
RESET
7F
Resets the Amplifier Unit.
Response Code List
Type
Response
code
Name
Description
Normal end
00
Normal end
Command execution is completed normally.
Host commu-
nications error
14
Format error
There is a mistake in the command format. (For example, the command
code is undefined, or the page or address specification is inappropriate.)
Communica-
tions error
70
Communications error
Noise or another hindrance occurs during communications with an ID
Tag, and communications cannot be completed normally.
71
Verification error
Correct data cannot be written to an ID Tag.
72
No Tag error
Either there is no ID Tag in front of the CIDRW Head, or the CIDRW
Head is unable to detect the ID Tag due to environmental factors (e.g.,
noise).
7B
Outside write area error A write operation was not completed normally because the ID Tag was
in an area in which the ID Tag could be read but not written.
7E
ID system error (1)
The ID Tag is in a status where it cannot execute command processing.
7F
ID system error (2)
An inapplicable ID Tag has been used.
Содержание V640-HS61
Страница 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Страница 76: ...74 SECTION 3 Communications Test CIDRW System User s Manual SECTION 3 Preparing for Communications...
Страница 106: ...104 SECTION 4 When SECS Is Not Used CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags...
Страница 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Страница 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Страница 173: ......