SECTION 3
Preparing for Communications
Check for Correct Setting
The currently set data can be output so that you can check if it is correct.
1.
Send the parameter output command "::GET_E99SYS"
from the host device.
The current operation parameter settings are displayed.
Do not change operation parameters other than RT, CIDOF,
and CIDLN. This can cause the system to stop operating
correctly.
For the V700-L22-V2, the “NVASC” parameter is added
to the end.
::GET_E99SYS
RT=10.0
CT=0.1
RTY=3
DINST=
MENT=
MODEL=L22
HREV=001.04
CIDOF=00
CIDLN=16
::END
_
V700-L22 Operation Example
RT=10.0
CT=0.1
RTY=3
DINST=
MENT=
MODEL=L22V2
HREV=001.00
CIDOF=00
CIDLN=16
NVASC=NOM
::END
V700-L22-V2 Operation Example