74
10. Pulse counter
Programming the pulse counter
Use the programming software to select the currency of your choice: EUR or GBP. Gas and water consumption are
expressed in m³, and electricity in kWh. The following settings can be selected per channel:
• channel name.
• channel type: gas, water, electricity.
• pulse conversion factor:
• 1 - 1000 pulses/m³ for gas and water.
• 1 - 10 000 pulses/kWh for electricity.
• for electricity: global, consumer, amount generated.
Error codes
When the module is functioning properly, the STATUS LED will light up in TEST mode only. If one or several errors occur,
the LED will blink to indicate the error code of the error with the highest priority. The table below provides an overview of
all error codes.
Technical data
• maximum pulse frequency per input: 10 Hz
• minimum pulse duration: 30 ms
• only for meters with a pulse output isolated from the mains in accordance with SELV requirements
• screw terminals for 3 x 1.5 mm² or 2 x 2 mm² or 1 x 4 mm²
• sliding contact
• dimensions: DIN 2U
• CE marking
• ambient temperature: 0 - 45°C
• If the voltage at the power supply of the Niko Home Control installation is disrupted, no data will be logged,
even if electricity is still being consumed or produced by the switching circuits measured.
• You will lose all data of a channel if you use the programming software to:
• remove the channel.
• change the energy type (electricity/gas/water).
• change the measurement type.
LED
ACTION
ERROR
POSSIBLE CAUSES
STATUS LED
Blinks – one pulse per two
seconds.
Communication
error
The module is faulty or nothing has been
connected to the connection terminals.