10. Pulse counter
71
10. Pulse counter
Description
The pulse counter allows you to monitor gas, water and electricity consumption as well as electricity production.
Overview
Operation
This module has three pulse inputs and can be connected to up to three meters. The pulse counter counts the pulses and
converts the sum into m³ or kWh.
The scale factor of the pulses (e.g. 1 pulse = 10 litres) and the meter type (gas, water or electricity) can be selected via
the programming software.
The eco-display shows the total electricity consumption and the electricity production, if applicable. If you want to keep
track of your home’s past electricity consumption, then the installation must be fitted with an IP module that logs the
measuring data. A detailed overview of these data can be requested via the touchscreen, a smartphone or the Niko Home
Control energy software.
550-00250
A.
Screw terminals 1 -3
This is where you can connect three pulse inputs. Each
pulse input must be connected to the pulse output of a
meter.
B.
Screw terminal COM
This is where you connect the mass of the pulse output.
C.
Sliding contact
The sliding contact is used for connecting the next module,
which means that the bus and the power supply module are
then also interconnected.
D.
ADDRESS button
This button is used while programming the installation to
send the unique address of the module during the
addressing phase.
E.
CHANNEL LEDs
One LED per channel. The CHANNEL LED lights up in TEST
mode when the pulse counter detects a pulse from the
meter.
F.
STATUS LED
The STATUS LED lights up in TEST mode when the module
is connected correctly and is functioning properly. If an error
occurs, the LED will blink to indicate an error code. See
Error codes on page 74
.
The pulse counter should not be used for billing purposes. Only the data recorded by the meter of the energy
supplier are valid for billing purposes. The data recorded by the pulse counter should be used for information
purposes only.
E
D
C
A
F
B
Содержание 550-00001
Страница 1: ...Installation Manual Niko Home Control...
Страница 17: ...16 3 Power supply Installation Connection diagram N L 230V...
Страница 65: ...64 9 Electricity measuring modules Measuring one or several switching circuits 230V L N 0 3 0 9 1 7 kWh L K...
Страница 122: ...20 Digital potential free sensor module 121 Installation Connection diagram ALARM 350 10032...