136
25. RF interface Easywave
Operation
This modular receiver allows a connection to be established between Niko wireless Easywave controls and the Niko Home
Control installation. The transfer takes place via radio waves on the licence-free ISM frequency band 868.3 MHz
according to the European standard. This frequency only allows products that emit signals no more than 1 % per hour,
which reduces the risk of interrupted signals to an absolute minimum.
The system consists of a modular set-up including transmitters and one receiver. The wall transmitters are shaped like
switches and are mounted onto the wall. The hand-held transmitters are shaped like traditional remote controls.
These products are manufactured in conformity with EU regulations and meet all the requirements of R&TTE
directive 1999/5/EC.
Signal range
Signals from devices for which a remote control is used, such as TVs, video and audio, will not be interrupted by Easywave
transmitters. Easywave transmitters do not require to be positioned to point towards the receiver. Indoors, the signal range
is approx. 30 m, In open field, the signal range is approx. 100 m. The signal range also depends on the materials used in
the construction of the building.
A diagnostic device (05-370) can be used to determine the RF signal strength within a certain area. The device recognises
all 868.3 MHz signals. The nine LEDs on the device will indicate the quality of the signals received or the strength of any
interrupting signals. This allows you to determine whether or not the signal range of the RF transmitter will meet your
needs.
Use single-button controls only. Program a different button for each action.
A.
brick, concrete
Loss of 20 to 40 %
B.
wood, plaster walls
Loss of 5 to 20 %
C.
reinforced concrete
Loss of 40 to 90 %
D.
confined metal space
Loss of 90 to 100 %
A
B
C
D
Содержание 550-00001
Страница 1: ...Installation Manual Niko Home Control...
Страница 17: ...16 3 Power supply Installation Connection diagram N L 230V...
Страница 65: ...64 9 Electricity measuring modules Measuring one or several switching circuits 230V L N 0 3 0 9 1 7 kWh L K...