72
10. Pulse counter
Selecting the correct measuring module
There are a few options available for measuring electrical data. Based on the number and type of channels you wish to
measure, you can either select an electricity measuring module with one channel, an electricity measuring module with
three channels, or a pulse counter for three channels in conjunction with a meter with pulse output. See
Electricity
measuring modules on page 59
.
If the Niko Home Control installation is fitted with an IP module, then this module can be used to store measuring data.
How long the IP module will store this data for will depend on the number of channels in the installation. An overview is
provided in the table below.
If the resident wishes to store this data for an extended period of time, then he or she
must export this data using the Niko Home Control user settings software before the existing data will be overwritten.
Installation
Connection diagram
A maximum of 20 channels can be measured per installation.
Number of channels
Storage capacity of the IP module
3
9 years
9
3 years
15
1.5 years
20
1 year
A
30°C
Qn2,5 m³/h
D 92
6.131.07
Содержание 550-00001
Страница 1: ...Installation Manual Niko Home Control...
Страница 17: ...16 3 Power supply Installation Connection diagram N L 230V...
Страница 65: ...64 9 Electricity measuring modules Measuring one or several switching circuits 230V L N 0 3 0 9 1 7 kWh L K...
Страница 122: ...20 Digital potential free sensor module 121 Installation Connection diagram ALARM 350 10032...