24. Nikobus interface
133
Installation
Connection diagram
Follow the steps below to install the Nikobus interface:
1
Press the Nikobus interface onto the DIN rail until it clicks into place. Preferably position the interface in the top row
inside the electrical cabinet to keep the cables separate from the 230V cables.
2
Connect the Nikobus cables to screw terminals B1 and B2.
Error codes
When the module is functioning properly, the NIKOBUS LED will light up in rest mode and the STATUS LED of the module
will light up in TEST mode only. If one or several errors occur, the STATUS LED will blink to indicate the error code of the
error with the highest priority. The table below provides an overview of all error codes.
• Ensure that the installation is disconnected from the power mains when setting up the electrical cabinet.
• The bus cables of the Nikobus installation are not compatible with those of the Niko Home Control
installation. Connecting cables from both systems to one another may cause damage.
LED
ACTION
ERROR
POSSIBLE SOLUTIONS
STATUS LED
Blinks – one pulse per two
seconds.
Software error
Wrong software version.*
*Download the latest software version
from the Niko website to upgrade the
module.
Blinks – two pulses per two
seconds.
No Nikobus voltage
detected.
Check the cables.
Check whether the Nikobus installation is
functioning properly.
Add a Nikobus module to supply bus
power.
NIKOBUS LED
Does not light up.
Содержание 550-00001
Страница 1: ...Installation Manual Niko Home Control...
Страница 17: ...16 3 Power supply Installation Connection diagram N L 230V...
Страница 65: ...64 9 Electricity measuring modules Measuring one or several switching circuits 230V L N 0 3 0 9 1 7 kWh L K...
Страница 122: ...20 Digital potential free sensor module 121 Installation Connection diagram ALARM 350 10032...