84
SI-Ethernet User Guide
Issue: 3
Sets the application tolerable clock jitter in ns from the grandmaster. If
Sync Jitter From
Grandmaster
(
S.11.006
) is within the tolerance the local clock is used and
Module Synchronised
Flag
(
S.11.008
) is set to 1 and synchronized cyclic data links will be processed.
This parameter displays the module's synchronization status. 1 = Synchronized, 0 = Not
synchronized.
This parameter controls whether the module synchronizes with the network grandmaster. A value
of On inhibits this.
This parameter displays the current date. If the module has no time source it will display the date
based on its power-up date of 1st January 1970.
S.11.007
Sync Jitter Threshold
Minimum
500
Maximum
1000000
Default
1000
Units
ns
Type
32 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
S.11.008
Module Sync Flag
Minimum
0
(Display: Off)
Maximum
1
(Display: On)
Default
0
(Display: Off)
Units
None
Type
1 Bit Volatile
Update Rate
Written every 10 ms
Display Format
None
Decimal Places
0
Coding
RO
S.11.009
Inhibit Drive Synchronisation
Minimum
0
(Display: Off)
Maximum
1
(Display: On)
Default
0
(Display: Off)
Units
None
Type
1 Bit User Save
Update Rate
Immediate
Display Format
None
Decimal Places
0
Coding
RW
S.11.010
PTP Date
Minimum
0
(Display: 00-00-00)
Maximum
311299
(Display: 31-12-99)
Default
None
Units
None
Type
32 Bit Volatile
Update Rate
Written every 500 ms
Display Format
Date
Decimal Places
0
Coding
RO, ND, NC, PT, BU