36
SI-Ethernet User Guide
Issue: 3
6
Parameters
The Ethernet interface holds two parameter databases; the Ethernet interface internal parameter
database and the host drive's parameter database.
The Ethernet interface internal parameters can be accessed from the drive's keypad, a user
program in a MCi200/MCi210 option module, PC Tools applications software or a module in
another slot of the drive. The notation
S.mm.ppp
is used to access these parameters where
S
is
the slot number,
mm
is the menu number and
ppp
is the parameter number. For example, to
access Pr
02.004
of a MCi210 installed in slot 2 of a drive from a module in slot 3, it will be
accessed using Pr
2.02.004.
The Ethernet interface will also hold a copy of the host drive's database. At power up, if the stored
drive database is different to that of the drive, the Ethernet interface will upload the drive's database
and overwrite the stored database. If the two databases match, the drive's database will not be
uploaded.
A module that is powered up for the first time will not contain a drive database and therefore will
perform a drive database upload.
6.1
Full parameter descriptions
6.1.1
Menu 0 - Module setup
The Module ID:
•
Onboard Ethernet = 430
•
SI-Ethernet option module = 433
Module firmware version in
ww.xx.yy.zz
format.
S.00.001
Module ID
Minimum
0
Maximum
65535
Default
None
Units
None
Type
16 Bit Volatile
Update Rate
Power-up write
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT, BU
S.00.002
Software Version
Minimum
0
(Display 00.00.00.00)
Maximum
99999999
(Display 99.99.99.99)
Default
None
Units
None
Type
32 Bit Volatile
Update Rate
Written on module
initialization
Display Format
Version Number
Decimal Places
0
Coding
RO, ND, NC, PT
Содержание Unidrive M600
Страница 1: ...User Guide SI Ethernet and Unidrive M Onboard Ethernet Part Number 0478 0137 03 Issue 3 ...
Страница 16: ...16 SI Ethernet User Guide Issue 3 Figure 4 3 Typical network topologies ...
Страница 215: ......
Страница 216: ...0478 0137 03 ...