SI-Ethernet User Guide
75
Issue: 3
Sa
fe
In
Me
ch
E
G
Par
amet
er
Key
an
PC T
Sec
Di
G
Ind
ex
Defines the action to be taken for a timeout on the Rx2 link.
This parameter defines the slot in which an event will occur if a cyclic data timeout occurs on the
Rx2 link.
S.10.056
Rx2 Timeout Action
Minimum
0
(Display: Trip)
Maximum
2
(Display: Hold last)
Default
0
(Display: Trip)
Units
None
Type
8 Bit User save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
Trip
Trip drive with Slx.Er and sub-trip code 106 (Cyclic Timeout)
1
Clear output
PLC output parameters will have their values set to zero
2
Hold last
Hold the last value in output parameters
S.10.057
Rx2 Timeout Event Dest
Minimum
0
(Display: This slot)
Maximum
4
(Display: Slot 4)
Default
0
(Display: This slot)
Units
None
Type
8 Bit User save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
This slot
Trigger module event in this slot
1
Slot 1
Trigger module event in slot 1
2
Slot 2
Trigger module event in slot 2
3
Slot 3
Trigger module event in slot 3
4
Slot 4
Trigger module event in slot 4
This feature is not yet implemented.
NOTE
Содержание Unidrive M600
Страница 1: ...User Guide SI Ethernet and Unidrive M Onboard Ethernet Part Number 0478 0137 03 Issue 3 ...
Страница 16: ...16 SI Ethernet User Guide Issue 3 Figure 4 3 Typical network topologies ...
Страница 215: ......
Страница 216: ...0478 0137 03 ...