78
SI-Ethernet User Guide
Issue: 3
Used to select Rx3 as a standard or synchronous cyclic link.
This parameter is used to set the link number (1 to 255) for the Rx3 link.
This parameter sets the destination parameter for the Rx3 link.
This parameter is used to set the number of contiguous parameters for the Rx3 link.
S.10.060
Rx3 Link Profile
Minimum
0
(Display: Std)
Maximum
1
(Display: Sync)
Default
0
(Display: Std)
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt
Value
Text
Description
0
Std
Standard link
1
Sync
Synchronized link
S.10.061
Rx3 Link Number
Minimum
0
Maximum
255
Default
0
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
S.10.062
Rx3 Destination Parameter
Minimum
0
(Display: 0.00.000)
Maximum
499999
(Display: 4.99.999)
Default
0
(Display: 0.00.000)
Units
None
Type
32 Bit User Save
Update Rate
Read on reset
Display Format
Slot Menu Param
Decimal Places
0
Coding
RW, PT, BU
S.10.063
Rx3 Parameter Count
Minimum
0
Maximum
10
Default
0
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
Содержание Unidrive M600
Страница 1: ...User Guide SI Ethernet and Unidrive M Onboard Ethernet Part Number 0478 0137 03 Issue 3 ...
Страница 16: ...16 SI Ethernet User Guide Issue 3 Figure 4 3 Typical network topologies ...
Страница 215: ......
Страница 216: ...0478 0137 03 ...