68
SI-Ethernet User Guide
Issue: 3
This parameter is used to set the link number (1 to 255) for the Rx1 link.
This parameter sets the destination parameter for the Rx1 link.
This parameter is used to set the number of contiguous parameters for the Rx1 link.
S.10.041
Rx1 Link Number
Minimum
0
Maximum
255
Default
0
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
S.10.042
Rx1 Destination Parameter
Minimum
0
(Display: 0.00.000)
Maximum
499999
(Display: 4.99.999)
Default
0
(Display: 0.00.000)
Units
None
Type
32 Bit User Save
Update Rate
Read on reset
Display Format
Slot Menu Param
Decimal Places
0
Coding
RW, BU
S.10.043
Rx1 Parameter Count
Minimum
0
Maximum
10
Default
0
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU