102
SI-Ethernet User Guide
Issue: 3
This parameter defines the destination slot to trigger the event upon an RPI timeout.
Defines the event to trigger in the specified destination (
RPI timeout event destination
(
S.20.012
))
upon an RPI timeout.
S.20.012
RPI Timeout Event Dest
Minimum
0
(Display: This slot)
Maximum
4
(Display: Slot 4)
Default
0
(Display: This slot)
Units
None
Type
8 Bit User Save
Update Rate
Module reset, EtherNet/IP
interface reset or EtherNet/IP
interface enable
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
This slot
Trigger event in this slot
1
Slot 1
Trigger event in slot 1
2
Slot 2
Trigger event in slot 2
3
Slot 3
Trigger event in slot 3
4
Slot 4
Trigger event in slot 4
This feature is not yet implemented.
S.20.013
RPI timeout event type
Minimum
0
(Display: No event)
Maximum
5
(Display: Trigger Event 4)
Default
0
(Display: No event)
Units
None
Type
8 Bit User Save
Update Rate
Module reset, EtherNet/IP
interface reset or EtherNet/IP
interface enable
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
No event
No event
1
Trigger Event
Trigger module Event
2
Trigger Event 1
Trigger module Event 1
3
Trigger Event 2
Trigger module Event 2
4
Trigger Event 3
Trigger module Event 3
5
Trigger Event 4
Trigger module Event 4
NOTE
Содержание Unidrive M600
Страница 1: ...User Guide SI Ethernet and Unidrive M Onboard Ethernet Part Number 0478 0137 03 Issue 3 ...
Страница 16: ...16 SI Ethernet User Guide Issue 3 Figure 4 3 Typical network topologies ...
Страница 215: ......