SI-Ethernet User Guide
Issue: 3
Rx1 link.
Defines the event number to trigger in the given destination (slot) when a late synchronized frame
is received on the Rx1 link.
This parameter defines the action to be taken when a late synchronized frame is received on the
Rx2 link.
This feature is not yet implemented.
S.11.042
Rx1 Late Sync Frame Event
Minimum
0
(Display: No Event)
Maximum
4
(Display: Event3)
Default
0
(Display: No Event)
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
No Event
No event
1
Event
Trigger module event
2
Event1
Trigger module event 1
3
Event2
Trigger module event 2
4
Event3
Trigger module event 3
This feature is not yet implemented.
S.11.050
Rx2 Late Sync Frame Action
Minimum
1
(Display: Trip)
Maximum
3
(Display: Use)
Default
1
(Display: Trip)
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
1
Trip
Trip drive with Slx.Er and sub-trip code 107
2
Do not use
The data is ignored
3
Use
The data is used immediately
NOTE