40
SI-Ethernet User Guide
Issue: 3
6.1.2
Menu 2 - Ethernet configuration
This parameter indicates the status of the network that the module is connected to.
This parameter displays the number of frames that the module is transmitting and/or receiving
every second.
Controls whether or not the module will attempt to use a Dynamic Host Configuration Protocol
(DHCP) server to obtain the IP address, subnet mask, default gateway and DNS servers.
S.02.003
Network Status
Minimum
0
(Display: Initializing)
Maximum
5
(Display:
Active)
Default
None
Units
None
Type
8 Bit Volatile
Update Rate
Written every second
Display Format
None
Decimal Places
0
Coding
RO, Txt, ND, NC, PT, BU
Value
Text
Description
0
Initializing The network interface is being initialized
1
Links
Down
No link connection has been detected on either of the Ethernet ports
2
DHCP In
Progress
The module is attempting to obtain the IP address, subnet mask, default
gateway and DNS server addresses from a DHCP server
3
No
Address
The module does not have an IP address - either the user has not provided
one manually or one could not be allocated via DHCP
4
Ready
The network interface has been successfully configured but no data is
being received or transmitted
5
Active
The network interface is receiving or transmitting data
S.02.004
Network Message Count
Minimum
0
Maximum
65535
Default
None
Units
Messages/s
Type
16 Bit Volatile
Update Rate
Written every second
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT, BU
S.02.005
DHCP Enable
Minimum
0
(Display: Off)
Maximum
1
(Display: On)
Default
1
(Display: On)
Units
None
Type
1 Bit User Save
Update Rate
Background read
Display Format
None
Decimal Places
0
Coding
RW, BU
Содержание Unidrive M600