76
SI-Ethernet User Guide
Issue: 3
Defines the event to trigger in the given destination, as specified in
(S.10.057)
, if a cyclic data timeout occurs on the Rx2 link.
S.10.058
Rx2 Timeout Event Type
Minimum
0
(Display: No Event)
Maximum
4
(Display: Event3)
Default
0
(Display: No Event)
Units
None
Type
8 Bit User save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
No Event
No event
1
Event
Trigger module event
2
Event 1
Trigger module event 1
3
Event 2
Trigger module event 2
4
Event 3
Trigger module event 3
This feature is not yet implemented.
S.10.059
Rx2 Link Status
Minimum
-31
(Display: Disabled)
Maximum
2
(Display: OK sync)
Default
None
Units
None
Type
8 Bit Volatile
Update Rate
Write on reset
Display Format
None
Decimal Places
0
Coding
RO, Txt, NC, ND, PT
Value
Text
Description
-31
Disabled
Easy Mode protocol is disabled or link number set to 0
-30
VLAN disabled
VLAN is required in order to guarantee timing in
synchronous mode but it is disabled
-29
Reserved 29
Reserved for future use
-28
Reserved 28
Reserved for future use
-27
Reserved 27
Reserved for future use
-26
Reserved 26
Reserved for future use
-25
Reserved 25
Reserved for future use
-24
Reserved 24
Reserved for future use
-23
Reserved 23
Reserved for future use
NOTE