86
SI-Ethernet User Guide
Issue: 3
Duration that the jitter (
Synchronisation Jitter From Grandmaster
(
S.11.006
)) must be below the
jitter threshold for before the in sync flag (
Module Synchronised Flag
(
S.11.008
)) is set.
For a system the duration depends upon the number of IEEE1588 capable master devices on the
network. To use lower values here the number of devices which are capable of acting as a
synchronization master must be kept as low as possible by setting
Preferred Sync Master
(
S.11.001
) to 0 on all interfaces except those which may be master.
The parameter displays a count of network errors since startup. It can be used as an indication of a
problem.
This Interface does not support Slave mode.
S.11.017
In sync window length
Minimum
3
Maximum
255
Default
20
Units
Seconds
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
S.11.020
Network Error Count
Minimum
0
Maximum
4294967295
Default
None
Units
None
Type
32 Bit Volatile
Update Rate
Written every 500 ms
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT, BU
S.11.022
Interoption Sync Status
Minimum
0
(Display: MASTER)
Maximum
2
(Display: INDEPENDENT)
Default
0
(Display: MASTER)
Units
None
Type
8 Bit Volatile
Update Rate
Background
Display Format
None
Decimal Places
0
Coding
RO, Txt, ND, NC, PT, BU
Value
Text
Description
0
MASTER
The module is master but not producing
1
PRODUCER
The module is master and producing
2
INDEPENDENT
The module is not master