This specifies the type of transmission for the Rx1 link.
This parameter specifies the watchdog timer for the Rx1 link. If no cyclic data is received on the
Rx1 link the action taken will be determined by the setting in
Rx1 Timeout Action
(
S.10.046
).
S.10.044
Rx1 Source Type
Minimum
0
(Display: Unicast)
Maximum
11
(Display: Multicast10)
Default
0
(Display: Unicast)
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
Unicast
Link is unicast to the IP address specified
1
Broadcast
Link is broadcast (255.255.255.255)
2
Multicast1
Link is multicast to the IP address (239.255.0.1)
3
Multicast2
Link is multicast to the IP address (239.255.0.2)
4
Multicast3
Link is multicast to the IP address (239.255.0.3)
5
Multicast4
Link is multicast to the IP address (239.255.0.4)
6
Multicast5
Link is multicast to the IP address (239.255.0.5)
7
Multicast6
Link is multicast to the IP address (239.255.0.6)
8
Multicast7
Link is multicast to the IP address (239.255.0.7)
9
Multicast8
Link is multicast to the IP address (239.255.0.8)
10
Multicast9
Link is multicast to the IP address (239.255.0.9)
11
Multicast10
Link is multicast to the IP address (239.255.0.10)
S.10.045
Rx1 Timeout
Minimum
0
Maximum
65535
Default
100
Units
ms
Type
16 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
It is good system design to allow for some message loss by setting the timeout duration
to be greater than the transmit period by a factor of 2 or more.
NOTE