SI-Ethernet User Guide
103
Issue: 3
Sa
fe
In
Me
ch
E
G
Par
amet
er
Key
an
PC T
Sec
Di
G
Ind
ex
This parameter defines the action to be taken upon a PLC idle event.
This parameter defines the destination slot to trigger the event upon a PLC idle event.
This feature is not yet implemented.
S.20.015
PLC idle action
Minimum
0
(Display: Trip)
Maximum
4
(Display: No Action)
Default
4
(Display: No Action)
Units
None
Type
8 Bit User Save
Update Rate
Module reset, EtherNet/IP
interface reset or EtherNet/IP
interface enable
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
Trip
Trip drive with Slx.Er and sub-trip code 116
1
Send flt values
Send configured fault values to the output parameters
2
Clear output
PLC output parameters will have their values set to zero
3
Hold last
Hold the last value in output parameters
4
No Action
No action with output parameters
S.20.016
PLC idle event destination
Minimum
0
(Display: This slot)
Maximum
4
(Display: Slot 4)
Default
0
(Display: This slot)
Units
None
Type
8 Bit User Save
Update Rate
Module reset, EtherNet/IP
interface reset or EtherNet/IP
interface enable
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
This slot
Trigger event in this slot
1
Slot 1
Trigger event in slot 1
2
Slot 2
Trigger event in slot 2
3
Slot 3
Trigger event in slot 3
4
Slot 4
Trigger event in slot 4
This feature is not yet implemented.
NOTE
NOTE
Содержание Unidrive M600
Страница 1: ...User Guide SI Ethernet and Unidrive M Onboard Ethernet Part Number 0478 0137 03 Issue 3 ...
Страница 16: ...16 SI Ethernet User Guide Issue 3 Figure 4 3 Typical network topologies ...
Страница 215: ......
Страница 216: ...0478 0137 03 ...