52
SI-Ethernet User Guide
Issue: 3
This parameter is used to enable or disable the Easy Mode protocol interface.
This parameter is used to perform a warm reset of the Easy Mode protocol interface. When set and
the protocol has reset, the parameter will be reset to zero (Off).
This parameter allows the protocol to be defaulted to factory settings. This includes all of the
protocol features, configuration, mappings and stored objects.
This parameter displays the total number of cyclic (Rx and Tx) messages per second.
S.10.001
Easy Mode Enable
Minimum
0
(Display: Off)
Maximum
1
(Display: On)
Default
1
(Display: On)
Units
None
Type
1 Bit User Save
Update Rate
Background read
Display Format
None
Decimal Places
0
Coding
RW, BU
S.10.002
Easy Mode Reset
Minimum
0
(Display: Off)
Maximum
1
(Display: On)
Default
0
(Display: Off)
Units
None
Type
1 Bit Volatile
Update Rate
Background read
Display Format
None
Decimal Places
0
Coding
RW, NC
S.10.003
Easy Mode Default
Minimum
0
(Display: Off)
Maximum
1
(Display: On)
Default
0
(Display: Off)
Units
None
Type
1 Bit Volatile
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, NC
S.10.004
Cyclic Messages Per Second
Minimum
0
Maximum
65535
Default
None
Units
Messages/s
Type
16 Bit Volatile
Update Rate
Background
Display Format
None
Decimal Places
0
Coding
RW, BU, PT, NC, ND