180
SI-Ethernet User Guide
Issue: 3
Motor type
Returns or sets the motor type to be used by the drive for instance 1.
Returns or sets the motor type to be used by the drive for instance 2.
Rated current
Returns or sets the rated motor current in Amps for instance 1. This attribute is linked to
Pr
0.05.007
.
Set
Pr
0.05.007
= RatedCurrent1 * 10.
Get
RatedCurrent1 = Pr
0.05.007
/ 10.
Returns or sets the rated motor current in Amps for instance 2. This attribute is linked to
Pr
0.21.007
.
Set
Pr
0.21.007
= RatedCurrent2 * 10.
Get RatedCurrent2 = Pr
0.21.007
/ 10.
Rated voltage
Returns or sets the rated motor voltage in Volts for instance 1. This attribute is linked to
Pr
0.05.009
.
Name:
MotorType1
Class
0x28
Default
7
Instance
0x01
Data Type
USINT
Attribute
0x03
Access
Get/Set
Name:
MotorType2
Class
0x28
Default
7
Instance
0x02
Data Type
USINT
Attribute
0x03
Access
Get/Set
Name:
RatedCurrent1
Class
0x28
Default
Pr
0.05.007
/ 10
Instance
0x01
Data Type
USINT
Attribute
0x06
Access
Get/Set
Name:
RatedCurrent2
Class
0x28
Default
Pr
0.21.007
/ 10
Instance
0x02
Data Type
USINT
Attribute
0x06
Access
Get/Set
Name:
RatedVoltage1
Class
0x28
Default
Pr
0.05.009
Instance
0x01
Data Type
USINT
Attribute
0x07
Access
Get/Set