58
SI-Ethernet User Guide
Issue: 3
Defines, in milliseconds, the rate at which Tx1 Link will be transmitted. A value of zero disables the
transmission of data.
For synchronous links, to support the Advanced Machine Controller, only values of 1, 2, 4, 8, 16 or
32 are valid.
S.10.016
Tx1 Message Rate
Minimum
0
Maximum
100
Default
0
Units
ms
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
S.10.019
Tx1 Link Status
Minimum
-31
(Display: Disabled)
Maximum
2
(Display: OK sync)
Default
None
Units
None
Type
8 Bit Volatile
Update Rate
Write on reset
Display Format
None
Decimal Places
0
Coding
RO, Txt, ND, NC, PT
Value
Text
Description
-31
Disabled
Easy Mode protocol is disabled or link number set to 0
-30
VLAN disabled
VLAN is required in order to guarantee timing in
synchronous mode but it is disabled
-29
Reserved 29
Reserved for future use
-28
Reserved 28
Reserved for future use
-27
Reserved 27
Reserved for future use
-26
Reserved 26
Reserved for future use
-25
Reserved 25
Reserved for future use
-24
Reserved 24
Reserved for future use
-23
Reserved 23
Reserved for future use
-22
Invalid DST IP
Destination IP address is invalid
-21
SYNC unsupported
Sync link does not support mappings to other option
parameters
-20
MEC offset
Incorrect MEC offset
-19
Invalid tx rate
Tx rate must be a factor of 1 second
-18
Too many mapping
The number of mapping items exceeds the range
supported
-17
Link busy
The link specified is busy
-16
Invalid profile
The profile is invalid
-15
Invalid mapping
The mapped parameter does not exist