91
ADVANCED PARAMETER-SETTING MODE
Commissioning manual Powerdrive MD2/FX
4617 en - 2017.09 / e
• Assignment of digital outputs and relay outputs
Relay
output 2
1
0
Output relay
2 invert
Output relay
2 state
Safe Torque
Off inputs
Digital I/O read word
Buffer 1
Buffer 2
Buffer 3
Buffer 4
Output relay
2 source
STO1
RL2
COM-RL2
Relay
output 1
1
0
Output relay
1 invert
Output relay
1 state
RL1
COM-RL1
Drive
healthy
Vmax
alarm
STO2
08.09
08.20
08.08
08.28
08.18
08.07
08.17
08.50
08.51
08.52
08.53
10.01
10.52
&
Output relay
1 source
08.27
Zero speed
Trip: Inconsistency
between STO inputs
DO1
1
0
DO1 reading
Digital output
1 invert
Digital
output 1
DO1 digital output source
08.16
08.06
10.03
08.26
Содержание LEROY-SOMER Powerdrive FX
Страница 1: ...4647 en 2017 09 e Powerdrive MD2 FX Commissioning manual R f rence...
Страница 41: ...41 QUICK SETUP MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 49: ...49 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 95: ...95 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 131: ...131 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e 5 14 MENU 13 Reserved...
Страница 137: ...137 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 174: ...174 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 175: ...175 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...