101
ADVANCED PARAMETER-SETTING MODE
Commissioning manual Powerdrive MD2/FX
4617 en - 2017.09 / e
09.61
: Logic function 3 out
Adjustment range : Disabled (0) or Enabled (1)
Format: 8 bits
Indicates the state of the output of logic function 3.
09.62
and
09.63
: Not used
09.64
: Logic function 3 source 1
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 1 for logic function 3.
Only «bit» type parameters can be used on these inputs.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.65
: Logic function 3 source 1 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 1 of logic function 3.
Disabled (0):
Source 1 not inverted.
Enabled (1):
Source 1 inverted.
09.66
: Logic function 3 source 2
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 2 for logic function 3.
Only «bit» type parameters can be used on these inputs.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.67
: Logic 3 source 2 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 2 of logic function 3.
Disabled (0):
Source 2 not inverted.
Enabled (1):
Source 2 inverted.
09.68
: Logic function 3 output invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert the output of logic function 3.
Disabled (0):
Output not inverted.
Enabled (1):
Output inverted.
09.69
: Not used
09.70
: Logic 4 output destination
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter defines the internal parameter which will be
assigned by the output of logic function 4.
Only non-protected «bit» type parameters can be addressed.
If an unsuitable parameter is programmed, the destination will
not be taken into account.
09.71
: Logic function 4 out
Adjustment range : Disabled (0) or Enabled (1)
Format: 8 bits
Indicates the state of the output of logic function 4.
09.72
and
09.73
: Not used
09.74
: Logic function 4 source 1
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 1 for logic function 4.
Only «bit» type parameters can be used on these inputs.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.75
: Logic function 4 source 1 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 1 of logic function 4.
Disabled (0):
Source 1 not inverted.
Enabled (1):
Source 1 inverted.
09.76
: Logic function 4 source 2
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 2 for logic function 4.
Only «bit» type parameters can be used on these inputs.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.77
: Logic function 4 source 2 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 2 of logic function 4.
Disabled (0):
Source 2 not inverted.
Enabled (1):
Source 2 inverted.
Содержание LEROY-SOMER Powerdrive FX
Страница 1: ...4647 en 2017 09 e Powerdrive MD2 FX Commissioning manual R f rence...
Страница 41: ...41 QUICK SETUP MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 49: ...49 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 95: ...95 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 131: ...131 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e 5 14 MENU 13 Reserved...
Страница 137: ...137 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 174: ...174 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...