102
ADVANCED PARAMETER-SETTING MODE
Commissioning manual Powerdrive MD2/FX
4617 en - 2017.09 / e
09.78
: Logic function 4 output invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert the output of logic function 4.
Disabled (0):
Output not inverted.
Enabled (1):
Output inverted.
09.79
: Not used
09.80
: Logic 5 output destination
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter defines the internal parameter which will be
assigned by the output of logic function 5.
Only non-protected «bit» type parameters can be addressed.
If an unsuitable parameter is programmed, the destination will
not be taken into account.
09.81
: Logic function 5 out
Adjustment range : Disabled (0) or Enabled (1)
Format: 8 bits
Indicates the state of the output of logic function 5.
09.82
: Logic function 5 source 3
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 3 for logic function 5.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.83
: Logic function 3 source 3 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 3 of logic function 5.
Disabled (0):
Source 3 not inverted.
Enabled (1):
Source 3 inverted.
09.84
: Logic function 5 source 1
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 1 for logic function 5.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.85
: Logic function 5 source 1 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 1 of logic function 5.
Disabled (0):
Source 1 not inverted.
Enabled (1):
Source 1 inverted.
09.86
: Logic function 5 source 2
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 2 for logic function 5.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.87
: Logic function 5 source 2 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 2 of logic function 5.
Disabled (0):
Source 2 not inverted.
Enabled (1):
Source 2 inverted.
09.88
: Logic function 5 output invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert the output of logic function 5.
09.89
: Not used
09.90
: Logic function 6 destination
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 8 bits
This parameter defines the internal parameter which will be
assigned by the output of logic function 6.
Only non-protected «bit» type parameters can be addressed.
If an unsuitable parameter is programmed, the destination will
not be taken into account.
09.91
: Logic function 6 out
Adjustment range : Disabled (0) or Enabled (1)
Format: 8 bits
Indicates the state of the output of logic function 6.
Содержание LEROY-SOMER Powerdrive FX
Страница 1: ...4647 en 2017 09 e Powerdrive MD2 FX Commissioning manual R f rence...
Страница 41: ...41 QUICK SETUP MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 49: ...49 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 95: ...95 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 131: ...131 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e 5 14 MENU 13 Reserved...
Страница 137: ...137 ADVANCED PARAMETER SETTING MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 174: ...174 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Страница 175: ...175 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...