177
DOS Coast Time
Time that Data Detect can be lost before
unmute
CHANGE:RADIO:SIG:MDC:OPT
Auto Timed Mute
Duration
Length of auto-mute on Carrier Detect
CHANGE:RADIO:SIG:MDC:OPT
MDC OPTIONS DECODE CHANNEL
Auto Reset Timer
Radio-wide setup of Auto Reset Timer length
CHANGE:RADIO:SYS CONFIG
Stat-Alert/ATIS Sel Cal
Enables Select Call for the current channel
CHANGE:CHANNEL
PTT-ID
Enables PTT-ID Encode for the current channel
CHANGE:CHANNEL
MDC/STAR/ATIS
Decode
Enables Signalling Decode for the current
channel
CHANGE:CHANNEL
Talkaround
Incompatible with PTT-ID and RAT if enabled
CHANGE:CHANNEL
Repeater Access
Enables Repeater Access for the current channel
CHANGE:CHANNEL
Signalling Muting
Dispatch
Sets whether the radio responds to only
Selective Calls or to normal condition as well
CHANGE:CHANNEL:OPT
Accept Alert
Enables chirp when RAT Side Button is pressed
CHANGE:RADIO:SIG:MDC:RAT ID
Silent Pretime
Sets Pretime between Keyup and first bit of RAT
data
CHANGE:RADIO:SIG:MDC:RAT ID
Code 1 - Code 8
Sets Repeater ID to be accessed
CHANGE:RADIO:SIG:MDC:RAT ID
MDC Decode Scan
Enables MDC Decoder in scan on MDC-
enabled channels
CHANGE:RADIO:SCAN:CONFIG
MDC Sel Call Scan
Enables scanning for MDC Sel-Cal on MDC-
enabled channels
CHANGE:RADIO:SCAN:CONFIG
Remote Monitor
Enables radio to respond to the MDC Remote
Monitor command
CHANGE:RADIO:SIG:MDC CONFIG
Sticky Revert
Enables radio to operate in the Sticky Revert
Mode when MDC Emergency Revert is used
CHANGE:RADIO:SIG:MDC CONFIG
Sticky Revert Alert
Enables radio to generate Alert Tone whenever
Operator keys up on the Sticky Revert Channel,
which may be different from the selected
channel
CHANGE:RADIO:SIG:MDC:CONFIG
Open Mic Duration
Enables radio to automatically key up with
Open Microphone for a programmable amount
of time after MDC Emergency Alarm Sequence
is completed
CHANGE:RADIO:SIG:MDC:OPT
Mandown Pre-Alert
Delay
Length of time from the point that the
mandown switch is pressed until the time that
an alert is generated
CHANGE:RADIO:SIG:MDC:OPT
Mandown Post-Alert
Delay
Length of time between the mandown alert
tone and transmission of the Emergency Alarm
sequence
CHANGE:RADIO:SIG:MDC:OPT
MDC Signalling
Field
Function
Location
Содержание HT 1000
Страница 4: ...Notes ...
Страница 72: ...66 Notes ...
Страница 162: ...156 Notes ...
Страница 172: ...166 Notes ...
Страница 174: ...168 Notes ...
Страница 176: ...170 Notes ...
Страница 178: ...172 Notes ...
Страница 190: ...184 Notes ...
Страница 202: ...196 Notes ...
Страница 205: ... 6881073C55 68P81073C55 F Motorola Inc 8000 West Sunrise Boulevard Fort Lauderdale FL 33322 ...