B-70 MANUAL OPERATION
13-7
Turret 1 Z-axis Zero Point Adjustment (ZL-253)
If it becomes necessary to adjust the zero point of turret 1 Z-axis due to the occurrence of trouble
or other reasons, the tailstock joint position cannot be established, either. In this case, establish
the tailstock joint position by following the procedure indicated below.
If it becomes necessary to adjust the zero point of turret 1 Z-axis, always establish the
tailstock joint position by following the procedure indicated below. If an axis is moved
before establishing the tailstock joint position, the tailstock might be hit against the
turret causing damage to the machine.
<Adjustment procedure>
1)
Place the DOOR INTERLOCK key-switch in the
NORMAL
position.
2)
Close the front door.
3)
Place the PANEL key-switch in one of the positions
indicated below.
(ON)
(PANEL/EDIT)
4)
Press the HEAD CHANGE switch
(head 1) to
select turret 1.
5)
Display the OPERATION PANEL screen.
6)
Set "VALID" for ZERO POINT SET using the cursor
control keys.
CAUTION
DOOR INTERLOCK
NORMAL
RELEASE
ON
PANEL
/EDIT
OFF
PANEL
2
1
HEAD CHANGE
1