OPERATION PANELS A-59
5-13-2
Axis Feed Amount Selection Switches
The axis feed amount selection switches are used to
determine the axis feed amount per pulse when an axis is
moved with the manual pulse generator.
When the switch is pressed, the indicator in the switch is
lit.
<Axis feed amount per pulse>
1.
When the power is turned on, the setting of the axis feed amount selection switch
(
1) is selected to ensure safety.
2.
When the operation mode is changed from automatic to manual, the axis feed
amount selection switch
(
1) is selected to ensure safety.
5-13-3
Manual Pulse Generator
The manual pulse generator is used to move an axis in
the handle mode.
The amount of axis feed per graduation of the manual
pulse generator is set with the axis feed amount selection
switches.
The feed direction is determined by the direction in which
the manual pulse generator is turned.
Do not turn the manual pulse generator any faster than 5 rotations per second. If you
do, the axis will not stop immediately when the manual pulse generator is stopped and
the actual amount of axis feed will not coincide with the number of pulses generated.
This could damage the machine.
Setting
X-, Z- and
B-axes (S type)
C-axis (MC type)
1
0.001 mm
0.001
10
0.01 mm
0.01
100
0.1 mm
0.1
Direction in which
Manual Pulse
Generator Turned
Axis Travel Direction
Clockwise
+ (positive)
Counterclockwise
(negative)
x1
x10
x100
NOTE
x1
x1
CAUTION