A-24 OPERATION PANELS
When this switch is pressed, the indicator in the switch is lit and the tape mode is
selected.
In the tape mode, running a program using an external I/O device (tape reader or
personal computer) is possible.
1.
An external I/O device (such as a tape reader) is optional.
2.
Before starting operation in the tape mode, close the front door.
3.
The RS232C connector at the lower area of the operation panel
cannot be used for tape mode operation. To perform tape mode
operation, set the NC parameters following the steps indicated
below.
1)
Connect the cross-cable to the RS232C connector in the
electrical cabinet.
2)
Set the I/O channel.
I/O channel: NC parameter No. 20 = 0
3)
Set the communication parameters.
Communication parameters:
NC parameter No. 101, 102, 103
When this switch is pressed, the indicator in the switch is lit and the handle mode
is selected.
In the handle mode, the axis selected with the axis selection switch is moved as
the manual pulse generator is turned.
The axis feed amount per pulse conforms to the setting of the axis feed amount
selection switches.
Close the front door before carrying out handle feed operation.
When this switch is pressed, the indicator in the switch is lit and the jog mode is
selected.
In the jog mode, axes are moved at the jog feedrate.
An axis is moved while an AXIS DIRECTION switch is held down at the feedrate
set with the OVERRIDE dial. Setting is possible in 15 steps in the range of 0 to
1260 mm/min.
Close the front door before carrying out jog feed operation.
When this switch is pressed, the indicator in the switch is lit and the rapid
traverse mode is selected.
In the rapid traverse mode, axes are moved at the rapid traverse rate.
An axis is moved at the rapid traverse rate while an AXIS DIRECTION switch is
held down.
Close the front door before carrying out rapid traverse operation.
Switch
Function
TAPE
NOTE
H
NOTE
JOG
NOTE
RPD
NOTE